ASTM D5084 PDF

0 Comment

GeoTesting Express is a provider of Soil Testing Services – ASTM D, Standard Test Methods for Measurement of Hydraulic Conductivity of Saturated Porous. This standard is issued under the fixed designation D ; the number 1 This standard is under the jurisdiction of ASTM Committee D18 on Soil and. Using low hydraulic gradient is time- consuming. ▫ ASTM D suggests a maximum hydraulic gradient of 30 for soils with k ≤ 1 x cm/s.

Author: Arashiktilar Mosar
Country: Pakistan
Language: English (Spanish)
Genre: Literature
Published (Last): 10 July 2007
Pages: 187
PDF File Size: 18.99 Mb
ePub File Size: 17.80 Mb
ISBN: 455-8-60135-790-2
Downloads: 69860
Price: Free* [*Free Regsitration Required]
Uploader: Mitaxe

There are six alternate methods or hydraulic systems that may be used to measure the hydraulic conductivity. These hydraulic systems are as follows: Agencies that meet the criteria of Practice D are generally considered capable of competent and objective testing, sampling, inspection, etc.

The quality of the result produced by this standard is dependent of the competence of the personnel performing it and the suitability of the equipment and facilities used. Temperatures outside this range may be used; however, the user would have to determine the specific gravity of mercury and R T see In addition, d504 are representative of the significant digits that should generally be retained.

If the void ratio is changed, the hydraulic conductivity of the test specimen will likely change, see Appendix X2. Therefore, the results should be applied to field situations with caution and by qualified personnel. The key criterion is that the requirements covered in Section 5 have to be met. Tightening the temperature control. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user’s objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations.

In addition, they are representative of the significant digits that should generally be retained. The inch-pound units given in parentheses are mathematical conversions, which are provided for information purposes only and are not considered standard, unless specifically stated as standard, such as 0.

TOP Related Articles  PARACENTESE PDF

The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user’s objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. Properly shortening the length or enlarging the cross-sectional area, or both, of the test specimen. These hydraulic systems are as follows:. It is beyond the scope of this standard to consider significant digits used in analysis methods for engineering design.

Other approaches, such as use of higher hydraulic gradients, lower viscosity fluid, elimination of any possible chemical gradients and bacterial growth, and strict verification of leakage, may also be considered.

Hydraulic conductivity varies with varying void ratio, which changes when the effective stress changes.

Log In ‹ Craig H. Benson, PhD, PE — WordPress

Methods A, B, and C take a longer period-of-time, from a few days to a few weeks depending on the hydraulic conductivity. Link to Active This link will always route to the current Active version of the standard. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

The key criterion is that the requirements covered in Section 5 have to be met. The testing time is ultimately controlled by meeting the equilibrium criteria for each Method see 9. Other strategies, such as using higher viscosity fluid or properly decreasing the cross-sectional area of the test specimen, or both, may also be possible.

The adoption of unsteady state measurements by using high-accuracy equipment along with the rigorous analyses for determining the hydraulic parameters this approach reduces testing duration according to Zhang et al. Strategies that may be possible when dealing with such impervious materials may include the following.

ASTM D Standard

There are six alternate methods or hydraulic systems, that may be used to measure the hydraulic conductivity. Strategies that may be possible when dealing with such impervious materials may include axtm following: However, these test methods are only intended to be used when water is the permeant liquid. Other strategies, such as using higher viscosity fluid or properly decreasing the cross-sectional area of the test specimen, or both, may also be possible. Typically a test can be performed using Methods D, Astn, or F within two to three days.

TOP Related Articles  ED LEEDSKALNIN MAGNETIC CURRENT ILLUSTRATED PDF

ASTM D5084

Temperatures outside this range may be used, however, the user would have to determine the specific gravity of mercury and R T see Experience has sometimes shown that hydraulic conductivities measured on small test specimens are not necessarily the same as larger-scale values.

Permeation with other liquids, such as chemical wastes, can be accomplished using procedures similar to those described in these test methods. Reliable results depend on many factors; Practice D provides a means of evaluating some of those factors.

Other items, such as use of higher hydraulic gradients, lower viscosity fluid, elimination of any possible chemical gradients and bacterial growth, and strict verification of leakage, may also be considered. Users of this standard are cautioned that compliance with Practice D does not in itself assure reliable results.

Active view current version of standard. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. If the confining stress is less than the swell pressure, anomalous flow conditions my occur; for example, mercury column s move in the wrong direction. These hydraulic systems are ast follows:.

Historical Version s – view previous versions of standard. Link to Active This link will always route to the current Active version of the standard.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

These hydraulic systems are as follows: It is beyond the scope of this standard to consider significant digits used in analysis methods for engineering design.